VX Transformer Wiring

These heat resisting wires are suitable for operation between -20°C & 105°C and are resistant to most insulating varnishes, lubricating oil,  hydraulic oil and many alkalis.

They are ideal for use as tails in transformers and electric motors or wherever encapsulation and high temperatures are needed.

The conductors are tinned annealed copper to facilitate soldering.

The use of a special high temperature PVC compound avoids the hardening, embrittlement and fracture suffered by standard wire and cable compounds due to interaction with oils and chemicals

Specifications:

Type Conductor Area Nom r/t Min Diam Max Diam Max * Amps Voltage Rating
(No/mm) (mm²) (mm) (mm) (mm) (ac rms)
           
VX050 7/0.12 0.08 0.30 0.90 1.10 3.5 300
VX150 14/0.12 0.16 0.30 1.00 1.20 4.9 300
VX250 7/0.2 0.22 0.45 1.40 1.60 5.9 600
VX350 16/0.2 0.5 0.45 1.70 1.90 8.9 600
VX355 16/0.2 0.5 0.60 2.10 2.30 8.9 1000
VX450 24/0.2 0.75 0.75 2.45 2.75 10.5 1000
VX500 32/0.2 1 0.75 2.75 3.05 12.5 1200
VX650 63/0.2 2 0.75 3.15 3.45 18 1200
VX750 95/0.2 3 1.00 4.50 4.90 21.5 1500

* Single conductor in free air at an ambient of 30°C and allowing a conductor temperature rise of 10°C.

All dimensions are nominal unless otherwise specified

Bunched conductor constructions are nominal and may vary slightly in the number of strands and/or strand diameter